Measurement of Multiparameters using Anaesthesia Injector Based on Arm Processor

Author(s):

V. Ramesh Kumar , ADHIYAMAAN COLLEGE OF ENGINEERING; V. Santhana Lakshmi, ADHIYAMAAN COLLEGE OF ENGINEERING; G. Merlin Christy Rani, ADHIYAMAAN COLLEGE OF ENGINEERING; K. Mottaiyasamy, ADHIYAMAAN COLLEGE OF ENGINEERING

Keywords:

generally the patient should be anaesthetized while major operations are done. If the operations are performed for longer run, the anaesthesia cannot be given at a stretch. The amount of anaesthesia that is delivered to the patient is very important because the over dosage can threaten the life of the patient. If lower quantity is injected then at the time of surgical procedure patient may get conscious and they will feel the surgical pain. To overcome these problems, an automatic anaesthesia machine was designed using an ARM processor. This anaesthesia machine will be very much helpful in delivering the correct amount of anaesthesia in a particular period of time. In this method, a keypad is used for setting the amount of anaesthesia by the anaesthetist and it is delivered using a syringe pump. As soon as the value is entered, the microprocessor accesses the values and starts delivering the anaesthesia through the syringe pump by initiating the stepper motor. The stepper motor is used to drive the syringe pu

Abstract

generally the patient should be anaesthetized while major operations are done. If the operations are performed for longer run, the anaesthesia cannot be given at a stretch. The amount of anaesthesia that is delivered to the patient is very important because the over dosage can threaten the life of the patient. If lower quantity is injected then at the time of surgical procedure patient may get conscious and they will feel the surgical pain. To overcome these problems, an automatic anaesthesia machine was designed using an ARM processor. This anaesthesia machine will be very much helpful in delivering the correct amount of anaesthesia in a particular period of time. In this method, a keypad is used for setting the amount of anaesthesia by the anaesthetist and it is delivered using a syringe pump. As soon as the value is entered, the microprocessor accesses the values and starts delivering the anaesthesia through the syringe pump by initiating the stepper motor. The stepper motor is used to drive the syringe pump. According to the stepper motor rotation the amount of anaesthesia will be administered to the patient and if anything goes wrong the alarm will turn on to indicate that there is some problem with the machine.

Other Details

Paper ID: IJSRDV2I8113
Published in: Volume : 2, Issue : 8
Publication Date: 01/11/2014
Page(s): 131-133

Article Preview

Download Article