High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Experimental Analysis of Machining Parameters for EDM of AISI D3 Steel using Copper-Silver Alloy Electrode

Author(s):

Hardikkumar Prakashbhai Patel , Shankersinh Vaghela Bapu Institute of Technology, Gandhinagar-382650; Rajat Dave, Shankersinh Vaghela Bapu Institute of Technology, Gandhinagar-382650

Keywords:

Electro discharge machine, MRR, EWR, Overcut, Copper electrode

Abstract

Electrical discharge machining (EDM) is non-traditional machining processes. EDM process is based on thermoelectric energy between the work piece and a tool electrode. A pulse discharge occurs in a small gap between the work piece and the tool electrode and removes the unwanted material from the material through melting and vaporizing. The present work aims to study the effect of EDM input parameters like pulse on time, pulse off time and current on the performance measure like Electrode wear rate (EWR) and over cut during electro discharge machining of AISI D3 steel as work piece and copper-silver alloy as electrodes. Taguchi method will be employed for experimental work .The research work is expected to find out the best material that will lead to a minimum over cut and minimum (EWR). The design of experiments is based on Taguchi’s L9 orthogonal array.

Other Details

Paper ID: IJSRDV5I20090
Published in: Volume : 5, Issue : 2
Publication Date: 01/05/2017
Page(s): 26-29

Article Preview

Download Article