Abstract

The layout method of structural planning and layout requires no longer simplest creativeness and conceptual wondering but additionally sound understanding of science of structural engineering besides the information of Practical", which includes latest design codes bye legal guidelines subsidized up with the aid of sufficient experience, intuition and judgments.". The purpose of standards is to ensure and enhance the safety, keeping careful balance between economy and safety. In the present study multistory residential building in luck now India is designed (slab, beam, column, floor, wall, footings) using AutoCAD, E-tab, software. Find the stress analysis in slab, shear force for beam, lateral load, axial load, longitudinal load, seismic or wind and area reinforcement for the column and stair case, lift in these different force are acting and analysis and design, depending upon the reaction and height of the foundation level depend upon the site safe bearing capacity of the soil "because of balance motive designed the preserving wall on this task.. In order to design them ,it is important to first obtain the plan of the particular building that is , positioning of particular room ( Drawing room, bed room, kitchen, wash room, balcony , stair case and lift etc. ) Such that they serve their respective motive and additionally suiting to the requirement and comfort of the inhabitant."Such that they serve their respective motive and additionally suiting to the requirement and comfort of the inhabitant." There by depending on the suitability, plan layout of beam and the position of column are fixed. Thereafter, the loads are calculated namely the dead loads, which depend on the unit weight of the materials used concrete and steel and brick and live loads. Footings are design based on the safe bearing capacity of soil. For designing of column and beam, It is necessary to know the moment they are subjected to, one-way, two- way slab the end condition and the loading. From the slab, the loads are transferred to the them. Thereafter, the loads (mainly shear) from the beam are taken by the columns. Finally, the section must be checked and analyze for the entire four component with regard to strength and service ability.

Other Details

Paper ID: IJSRDV7I30450
Published in: Volume : 7, Issue : 3
Publication Date: 01/06/2019
Page(s): 688-695

Article Preview

Download Article