Irshad Ahmad , SRI SATYA SAI UNIVERSITY OF TECHNOLOGY & MEDICAL SCIENCES, SEHORE (M. P.); Omshankar Jhariya, SRI SATYA SAI UNIVERSITY OF TECHNOLOGY & MEDICAL SCIENCES, SEHORE (M. P.); Anil Verma, SRI SATYA SAI UNIVERSITY OF TECHNOLOGY & MEDICAL SCIENCES, SEHORE (M. P.); G. R. Selokar, SRI SATYA SAI UNIVERSITY OF TECHNOLOGY & MEDICAL SCIENCES, SEHORE (M. P.)

Keywords:

Interior Permanent Magnet Synchronous Motor, Water Cooling Jacket, CFD, ANSYS and Finite Element Analysis

Abstract

Computational fluid dynamics analysis of electrical and mechanical components is an important role for design of motors water- cooling jacket and for choosing suitable cooling system to satisfied their optimum performance and reliability. Thermal behavior of IPMSM water-cooling jacket is depends on motor geometry. Computational fluid dynamics analysis of IPMSM motor with water-cooling jacket is being analysis by using ANSYS. Initially water-cooling three-dimensional solid model has been created in unigraphic & then finite element analysis is carried out in fluid flow fluent workbench of ANSYS. It is important to have an efficient cooling for the IPMSM to generate high heat dissipations. Velocity and temperature analysis in the solid modal of water-cooling jacket of IPMSM used in railway vehicle. The results obtained shows the effectiveness of the designed of the IPMSM water cooling jacket to its thermal behavior.