Analysis for The Accuracy of Thickness Measurement of Corrode Metal Plate by Ultrasonic Thickness Gauge

Author(s):

Sheetal Kumar Dewangan , CHRISTIAN COLLAGE OF ENGINEERING AND TECHNOLOGY, BHILAI; Sandeep Kansari, BHARTI COLLAGE OF ENGINEERING AND TECHNOLOGY

Keywords:

NDT, UT, Corrosion

Abstract

This paper summarizes some of the major aspects of precision ultrasonic thickness gauging. Ultrasonic nondestructive testing (NDT) characterizing material thickness, integrity, or other physical properties by means of high-frequency sound waves has become a widely used technique for quality control. In thickness gauging, ultrasonic techniques permit quick and reliable measurement of thickness without requiring access to both sides of a part. During the thickness measurement of any corrode plate, the reading of ultrasonic equipment gives many different reading for each time of inspection at same position due to there non uniform surfaces. Any material whose thickness is lower than the low limit of the probe due to corrosion of metal piece will cause Measurement errors. Sometimes the displayed reading is twice as big as the actual thickness. To prevent these errors, the critical thin Materials should be measured repeatedly for verification. This paper looks at the root causes of poor performance with ultrasonic and suggests some methods to improve the situation.

Other Details

Paper ID: IJSRDV2I11114
Published in: Volume : 2, Issue : 11
Publication Date: 01/02/2015
Page(s): 152-160

Article Preview

Download Article