Experimental Investigation and CFD Analysis on Effect of Tabulators on Performance of Heat Exchanger |
Author(s): |
Indrajeet Kumar , R.K.D.F Institute of science & technology, bhopal; Dr. M. K Chopra, R.K.D.F Institute of science & technology, bhopal |
Keywords: |
CFD Analysis, Heat Exchanger |
Abstract |
Heat exchanger is an important device in all the thermal systems. The heat exchanger is widely used equipment in different industries such as process, petroleum refining, chemicals, pharmaceutical and paper etc. After studying different literature about heat exchanger and double pipe heat exchanger problem is identified as to perform simulation and experimental investigation of double pipe heat exchanger with inner twisted tape inserted different mass flow rate. The system has followed different types of flow arrangement and geometric dimension with circular tape to attain heat transferred in experimental result and compare with simulation result. The objective of these experiments is Performance analysis of double pipe heat exchanger with inner and outer twisted tape at different mass flow rate. The experimental set up consists of double pipe heat exchanger experiment. The apparatus includes tube-within-a-tube heat exchangers and twisted tape type inserted threaded thermocouple at each end, a water pump and electric motor. These methods used to find out the heat transfer rate from the surface and related temperature of fluid motions also used to find the effectiveness. |
Other Details |
Paper ID: IJSRDV6I30383 Published in: Volume : 6, Issue : 3 Publication Date: 01/06/2018 Page(s): 934-939 |