High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Simulation of Induction Furnace Comparison with Practical Induction Furnace

Author(s):

Jiten Chavda , Shantilal Shah Engineering College, Bhavnagar; Viralkumar Solanki, Shantilal Shah Engineering College, Bhavnagar

Keywords:

Induction furnace, Harmonics, THD, Simulation.

Abstract

In this paper, at first, a simulation of induction furnace model optimized resonant capacitor is designed for a practical induction furnace with parallel resonant inverter. Then rectifier and inverter snubber circuit are designed. And taken voltage, current, THD and power measured. This measured value comparison with actual working industry furnace data. and conclude that when furnace is not operate at full load that time its power factor is very low. And THD is high.

Other Details

Paper ID: IJSRDV1I3024
Published in: Volume : 1, Issue : 3
Publication Date: 01/06/2013
Page(s): 501-505

Article Preview

Download Article