Power Transient Response of EDFA as a function of Wavelength in the scenario of Wavelength Division Multiplexed System |
Author(s): |
| Simranjit Singh , UCoE Patiala, Punjab, India; Prabhjyot Singh, UCoE Patiala, Punjab, India |
Keywords: |
| EDFA transient, Power excursions, WDM optical networks, add/drop (disturbing) channels. |
Abstract |
|
In this paper power transient is investigated as function of add/drop wavelength and surviving channel wavelength. We have reported that power excursions varies with different wavelength allocations of the add/drop channels. Transient response is reduced by 73.39% in case when add/drop channels are taken in L band instead of C band. Also power transient response is calculated as a function of wavelengths of surviving channel. It has been observed that at higher wavelengths power excursions are less than at shorter wavelengths of C band. |
Other Details |
|
Paper ID: IJSRDV1I9057 Published in: Volume : 1, Issue : 9 Publication Date: 01/12/2013 Page(s): 1919-1924 |