High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Seismic Evaluation of Multi-Storeyed R C Framed Structural System with the Influence of Different Shear Walls and Soft Storeys

Author(s):

Kalappa M. Sutar , Poojya Doddappa Appa College of Engineering; Vishwanath B. Patil , Poojya Doddappa Appa College of Engineering

Keywords:

Bare frame Masonry infill, Shear wall, Soft Story

Abstract

Masonry infills are normally considered as non-structural elements and their stiffness contributions are generally ignored in practice. But they affect both the structural and non-structural performance of the RC buildings during earthquakes. RC frame building with open first storey is known as soft storey, which performs poorly during strong earthquake shaking. A similar soft storey effect can occur if first and second story used as service story. Hence a combination of two structural system components i.e. Rigid frames and RC shear walls leads to a highly efficient system in which shear wall resist the majority of the lateral loads and the frame supports majority of the gravity loads. To study the effect of masonry infill with different soft storey level, 9 models of Reinforced Concrete framed building were analyzed with two types of shear wall when subjected to earthquake loading. The results of bare frame and other building models have been compared, it is observed that model with swastika and L shape shear wall with core wall are showing efficient performance and hence reducing the effect of soft storey in model3, model4 and model5

Other Details

Paper ID: IJSRDV2I6279
Published in: Volume : 2, Issue : 6
Publication Date: 01/09/2014
Page(s): 648-651

Article Preview

Download Article