Analysis and Simulation of Single Phase and Three Phase Seven Level Inverter

Author(s):

Upvan Tamrakar , S.A.T.I. Vidisha M.P. INDIA; C. S. Sharma, S.A.T.I. Vidisha M.P. INDIA; Sudhir Phulambrikar, S.A.T.I. Vidisha M.P. INDIA

Keywords:

Asymmetric CMLI, level shifted PWM, THD, PD POD, APOD, RL load

Abstract

This paper present a asymmetrical cascaded 7 level multiinverter using fixed frequency carrier based pulse width modulation technique.The multilevel inverter is used to reduce harmonics. Here we are comparing single phase 7 levels and 3 phase seven level topology and thus reducing THD less than 5%. In asymmetical cascaded single phase MLI by using only 2-H bridges with 8 switches we can get 7 level output voltage where as cascaded three phase MLI 7 level output voltage is obtained by using 6-H bridges with 24 switches.

Other Details

Paper ID: IJSRDV2I7095
Published in: Volume : 2, Issue : 7
Publication Date: 01/10/2014
Page(s): 234-237

Article Preview