Abstract

Waste heat recovery boiler system is better option for recovering heat from unused engine exhaust. Diverter dampers are used to divert the flue gases from engine exhaust either to the waste heat recovery boiler system or to the bypass system. We have considered the diverter damper with 200 mm diameter opening. The media which is the flue gases from the engine exhaust having temperature of around 500oC. This paper discusses the thermal analysis of the diverter damper which gives us the temperature distribution and thermal stresses induced in it. Steady state thermal analysis is assumed. By using the analysis software Ansys Workbench V14.0, color results are generated.