Enhancement of Boiler Efficiency for Industrial Boiler by Energy Audit |
Author(s): |
| Mrs. Nishadevi N. Jadeja , GOVT. ENGINEERING COLLEGE BHAVNAGAR; Mrs. Nishadevi N. Jadeja, GOVT. ENGINEERING COLLEGE BHAVNAGAR; Mr. Sanjay H. Zala, GOVT. ENGINEERING COLLEGE BHAVNAGAR; Mr. Vijay M. Parmar, M.S.University |
Keywords: |
| Industrial Boiler, Boiler Efficiency |
Abstract |
|
Boiler efficiency and energy losses from boiler are important parameter for any industry using boiler. In this paper a detailed analysis is carried out for combined water and fire tube boiler using biomass coal as fuel. Boiler efficiency calculated by direct method is in range of (78.5% to 81.6%). Major losses from boiler are heat loss due to radiation and convection from non-insulated surfaces (4.8% to 6.3%), heat loss due to flue gas (6.3% to 6.4%), heat loss due to blow down (0.263 to 0.398%), heat loss due to incomplete combustion (1.87% to 2.21%), heat loss due to unburnt coal in bottom ash (1.74 % to 1.86) and heat loss due to moisture present in fuel (1.3% to 1.6%). |
Other Details |
|
Paper ID: IJSRDV4I100266 Published in: Volume : 4, Issue : 10 Publication Date: 01/01/2017 Page(s): 296-300 |