Perfomance Measurement of Window Air Conditioner by Introducing Thermoelectric Module |
Author(s): |
| Kalpesh.V.Modi , Government Engineering college,Valsad; Samarth S. Pathak, Government Engineering college,Valsad; Pratik C. Prajapati, Government Engineering college,Valsad; Yagnik R. Patel, Government Engineering college,Valsad; Yash R. Gandhi, Government Engineering college,Valsad |
Keywords: |
| Energy crisis, Thermoelectric Module, Air conditioning |
Abstract |
|
In current scenario, energy crisis is the bottleneck for the growth of the nation. To meet the requirement of electricity, there are two ways either generation of more electricity or saving electricity. Here saving in electrical energy option has been adopted for the window air-conditioner (window air conditioning system) which can be possible by increasing the C.O.P. either by sub-cooling or superheating effect. In the present work, performance of window air conditioner has been measured without thermoelectric modules (TEM), by introducing single TEM and Two TEM which. TEM works on Peltier effect, which provides sub-cooling and superheating effect in window air conditioning system. The comparative study of obtained results was carried out for the window air conditioning system without TEM, with single TEM and with double TEM. |
Other Details |
|
Paper ID: IJSRDV4I40061 Published in: Volume : 4, Issue : 4 Publication Date: 01/07/2016 Page(s): 93-96 |