Bilal Haji , Marathwada Institute of Technology, Aurangabad; Pratiksha Shinde, Marathwada Institute of Technology, Aurangabad; Kiran Sapakal, Marathwada Institute of Technology, Aurangabad; Sachin Hapat, Marathwada Institute of Technology, Aurangabad; V. R. Upadhye, Marathwada Institute of Technology, Aurangabad |
Keywords: |
Lime Stone, OPC, Sand, Super Plasticizer |
Abstract |
Permeable concrete is used to improve the drainage system and erosion of soil due to runoff. In the present study, an attempt has been made how permeable concrete is beneficial over conventional concrete for the land where runoff is more. Material used in permeable concrete lime stone of size (4.75mm, 9.5mm, 12.5mm), OPC (53Grade), sand (7%of total aggregate volume), super plasticize er (430), it is found that the compressive strength of conventional concrete is 16.59 KN/mm2, 21.74 KN/mm2, 32.84 KN/mm2 and for permeable concrete it is 9.967 KN/mm2, 14.41 KN/mm2, 15.57 KN/mm2 for 7, 14, and 28 days respectively. From results compressive strength of conventional concrete is more as compare to permeable concrete but still can use at residential road, drive way, side walk, tennis court, parking area where the strength of concrete need not be more. |