Design and Analysis of Proportional Valve Solenoid |
Author(s): |
| Nilesh Patil , VJTI Matunga; Prof. W. S. Rathod, VJTI Matunga; Aniket L. Gaikwad, Fr. CRCE, Bandra, Mumbai |
Keywords: |
| Air gap, Dimensional characteristics, FEA, Proportional Solenoid (PS) |
Abstract |
|
The function of proportional valves is to provide a smooth and continuous variation in flow or pressure in response to an electrical input. This paper discusses the parameters that affect the force versus position characteristics and dynamic behavior of a proportional solenoid (PS), which include dimensional characteristics, the air gap, current density and magnetic materials. The FEA (Finite Element Analysis) provides a reliable numerical technique for analyzing engineering designs. Also, different current densities in a specific plunger position are studied to obtain optimal PS specifications. Additionally, the magnetic flux density and the distribution of flux lines are introduced for the actual material in a specific plunger position. Then, the simulation and experimental results are compared. |
Other Details |
|
Paper ID: IJSRDV4I50610 Published in: Volume : 4, Issue : 5 Publication Date: 01/08/2016 Page(s): 976-980 |