High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Design and Vibration Analysis of Existing Exhaust Fan using Finite element analysis Technique

Author(s):

Priyanka A. Gaikwad , Department of MechanicalEngineering, AbhaGaikwadPatil College of Engineering and Technology, Nagpur Maharashtra,India; Vivek Padole, Department of MechanicalEngineering, AbhaGaikwadPatil College of Engineering and Technology, Nagpur Maharashtra,India

Keywords:

Radiological, Pressure, Air Flow Rate, Chemical, Plant Equipment

Abstract

The process of removing and providing air by natural or mechanical means from a building is known as ventilation. It provides clean and fresh air in building, to maintain a thermally comfortable work environment and to remove airborne contaminants in the air. Generally, exhaust fans are used in the industries for ventilation. As we know that the physical movement or motion of a rotating machine is normally referred to as vibration. This paper based on the analysis of the vibration of existing industrial exhaust fan, in order to identified the resonance area in the design to avoid failure of the component due to high resonance and simultaneously to decrease vibrations and noise. We carried out modal analysis and static analysis of the existing exhaust fan to study natural frequencies, mode shapes and displacement.

Other Details

Paper ID: IJSRDV4I70263
Published in: Volume : 4, Issue : 7
Publication Date: 01/10/2016
Page(s): 476-478

Article Preview

Download Article