Analysis of Socket Connection between Precast Column and Cast in Place Footing by Using ANSYS |
Author(s): |
| Nageswari R , CHRIST KNOWLEDGE CITY |
Keywords: |
| Socket connection, Stiffener, Conventional column-Footing connection, Accelerated Bridge Construction (ABC) |
Abstract |
|
Nowadays, the transportation agencies are mostly using the Accelerated Bridge Construction (ABC) because it requires only little time to complete the works on the site as compared to the conventional cast in place system. This paper focuses on the analysis of socket connection between precast column and cast in place footing by using ANSYS. In this paper, it is planned to conduct a comparison between the socket connection with stiffener and conventional column – footing connection to determine the improved seismic performance of the socket connection between precast column and cast in place footing and also comparative study on the socket connection with stiffener by varying the diameter of the column are conducted. |
Other Details |
|
Paper ID: IJSRDV5I30772 Published in: Volume : 5, Issue : 3 Publication Date: 01/06/2017 Page(s): 704-708 |