High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Comparative Study of Seismic Performance of a Building with and without P-Delta Effect using Response Spectrum Analysis

Author(s):

Ravishankar V Lawate , PDACEG; Prof. Vishwanath. B. Patil, PDACEG

Keywords:

Soft Storey, P-delta effect, Equivalent Diagonal Strut, Moment Transfer Beams, Shear Wall

Abstract

The G+20 multi storey regular building is taken for present study. This building is modeled and analyzed by using ETABS V9.7.4. Assuming the material property as linear and non linear. The performance of the building is studied by comparing the base shear, displacement, storey drift in response spectrum analysis. Multi-storey buildings with open (soft) ground floor are inherently vulnerable to collapse due to earthquake load, even then their construction is still widespread in the developing nations. An investigation has been performed to study the behavior of the columns at ground level of multi-storey buildings with soft ground floor as satellite bus stop and moment transfer beams in all storey subjected to earthquake loading. The structural action of masonry infill panels of upper floors has also been taken into account by modeling them as diagonal struts. Shear wall is one of the most commonly used lateral load resisting in high rise building. In this study building is modeled with different shapes of shear wall with top and bottom soft storey.

Other Details

Paper ID: IJSRDV5I90101
Published in: Volume : 5, Issue : 9
Publication Date: 01/12/2017
Page(s): 62-66

Article Preview

Download Article