CFD Analysis of Solar Air Heater Duct using Broken Arc Shaped Ribs

Author(s):

Ashish Pal , SIRT Bhopal; N K Sagar, SIRT Bhopal

Keywords:

Reynolds Number, Heat Transfer, Pressure Drop, Duct, Relative Gap Position

Abstract

Artificial roughness in form of ribs is convenient method for enhancement of heat transfer coefficient in solar air heater. In this paper the CFD analysis on heat transfer and friction in rectangular ducts roughened with broken arc-rib roughness piece has been presented. The rib roughness has relative gap position (d/W) was varied from 0.20 to 0.80 and other parameter are constant. The effects of relative gap position on Nusselt number, friction factor and thermo-hydraulic performance parameter have been discussed and results compared with smooth duct and continuous arc rib roughened duct under similar conditions. The rough ribs were efficient enough to transfer the desired heat, but they are not economical and are very complex in design and construction. Whereas, the Circular ribs with different relative gap width gives more area of contact. So, there is enough time to transfer the heat from the ribs to the passing air which touches the ribs and the heat transfer takes place efficiently. It is found that the maximum heat transfer and friction characteristic at a relative gap position of 0.65.

Other Details

Paper ID: IJSRDV6I120434
Published in: Volume : 6, Issue : 12
Publication Date: 01/03/2019
Page(s): 547-552