High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Effect of Height Difference between Solar Thermal Collector and Storage Tank on the Entransy Destroyed

Author(s):

Wilfrid Coffi Adihou , University of Abomey-Calavi (B?nin); Malahimi Anjorin, University of Abomey-Calavi; Christophe Awanto, University of Abomey-Calavi; Aristide C. Houngan, University Institute of Technology (Lokossa); Emile Sanya, University of Abomey-Calavi

Keywords:

Solar Collector; Thermosiphon; Storage Tank; Level; Entransy Destroyed

Abstract

The difference in level between the top of the solar collector and the bottom of the storage tank is one of the parameters that can be used to improve the performance of a solar collector that operates by thermosiphon. The present research studies the influence of this factor on the criterion of entransy destroyed. The results of our analyzes showed that the distance between the top of the solar collector and the bottom of the storage tank recommended for a better performance is 1.1 m according to the entransy destroyed criterion.

Other Details

Paper ID: IJSRDV6I70077
Published in: Volume : 6, Issue : 7
Publication Date: 01/10/2018
Page(s): 720-727

Article Preview