Seismic Response of RC Structure with and without Floating Column |
Author(s): |
| Alok N , EAST WEST INSTITUTE OF TECHNOLOGY; Ms. Usha K N, EAST WEST INSTITUTE OF TECHNOLOGY |
Keywords: |
| ETABS software, RC Structure, Floating or Hanging Columns |
Abstract |
|
In recent times, multi-storey buildings in urban cities are required to have column free space due to shortage of space, population and also for aesthetic and functional requirements. For this buildings are provided with floating columns at one or more storey. These floating columns are highly disadvantageous in a building built in seismically active areas. The earthquake forces that are developed at different floor levels in a building need to be carried down along the height to the ground by the shortest path. Deviation or discontinuity in this load transfer path results in poor performance of the building. In the study the critical position of floating column will be analyzed for G+10 and G+15 RC buildings for zone II and zone V. Also the effect of size of beams and columns carrying the load of floating column has been assessed. The response of building such as storey drift, storey displacement and storey shear will be used to evaluate the results obtained using ETABS software. |
Other Details |
|
Paper ID: IJSRDV7I60240 Published in: Volume : 7, Issue : 6 Publication Date: 01/09/2019 Page(s): 607-613 |