High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Design of Circular over Head Tank for Surajkund Gorkhpur U.P. India

Author(s):

Shiva Chandra , Buddha Institute of Technology; Riddhi Dubey, Buddha Institute of Technology; Praveen Kumar, Buddha Institute of Technology; Manish Kumar, Buddha Institute of Technology; Mitesh Kumar Rawat , Buddha Institute of Technology

Keywords:

Over Head Tank, Ground Water Shource

Abstract

Today time tank are widely used for storing liquid like water chemical and petroleum etc. One of the best key water supply planning. Overhead tank are large quantity water store and most convenience used for rural areas. Overhead tank design of liquids retaining structures is based upon the fact that the concrete should not crack and hence the tensile strength of concrete should be within permissible limits. Every tank are designed as crack controlling structures to dislodge any leakage. Project gives in brief, the theory behind the design of liquid retaining structure (Elevated circular water tank) using LIMIT STRESS METHOD. Elements are design in limit state method. Join and reinforcement are listed in IS 3370: 2009. Our project overhead tank completed surajkund [GORAKHPUR].

Other Details

Paper ID: IJSRDV8I20404
Published in: Volume : 8, Issue : 2
Publication Date: 01/05/2020
Page(s): 572-574

Article Preview

Download Article