High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Study on Electronic Distance Measurement Device

Author(s):

Gaurav Kumar Jaiswal , Buddha Institute of Technology; Surya Prakash Sharma, Buddha Institute of Technology

Keywords:

EDM, Accuracy, Error specifications

Abstract

The paper deals with the construction and determination of coordinates of the absolute EDMs baseline in a laboratory with 16 pillars with forced centering. Leica Absolute Tracker AT401 (standard deviation of distance measurement: 5 µm, standard deviation of angle measurement: 0.15 mgon), which is designed for very accurate industrial measurements, was used for our purpose. Lengths between the baseline points were determined with a standard deviation of 0.02mm. The baseline is used for determining systematic and random errors of distance meters and for accuracy of distance meters at short distances common in engineering surveying for purposes of mechanical engineering.

Other Details

Paper ID: IJSRDV8I30765
Published in: Volume : 8, Issue : 3
Publication Date: 01/06/2020
Page(s): 633-636

Article Preview

Download Article