High Impact Factor : 4.396 icon | Submit Manuscript Online icon |

Analytical Study on Intz Water Tank Varying Height to Diameter Ratio of Cylindrical Wall

Author(s):

Himanshu Sharma , BM College of technology Indore; Mr. Mayur Singi, BM College of technology Indore

Keywords:

Stringer Beam, Truss Bridge, IRC loading, stresses on Beam & Slab

Abstract

Intz tank is an important overhead water storage tank, there for it is necessary that it should be constructed keeping in view its economy. The main aims of this paper are hydrostatic analysis of Intze water tank ,To obtain economical design of tank, the parametric study must needed, for this purpose we can vary the proportion of container such as, staging container diameter ratio, height of cylindrical wall to diameter ratio and horizontal angle of dome have been varied as well as no of column for design of staging .To achieve this objective 4 different depth to diameter ratio of Intze tank consider for analysis on staad pro software and comparative results obtained in term of principal and Von mises stresses on cylindrical wall. Maximum shear force and bending moment on beams and node displacement. For the parametric study of Intze tank horizontal angle of conical dome should be 45°, ratio of height of cylindrical wall to diameter ratio should be kept 0.5, 0.8, 1 and 1.5. with constant volume and height of staging.

Other Details

Paper ID: IJSRDV9I100017
Published in: Volume : 9, Issue : 10
Publication Date: 01/01/2022
Page(s): 23-27

Article Preview

Download Article